- Usually Ships 4 to 7 Business Days
BEA
Micro-Processed Low Energy Lock-Out Relay Module for SuperScan Approach 10LE21 by BEA
- Usually Ships 4 to 7 Business Days
- availability:
- available
North Shore Commercial Door now carries the 10LE21 Low Energy Micro-Processed Lock-Out Module for the SuperScan by BEA. The 10LE21 is designed to inhibit the approach SuperScan on an automatic door when the door is used manually. For instance, when the SuperScan is installed on a low energy operator that is to be used manually as well as automatically, the 10LE21 will allow the SuperScan to be active only when the door is triggered by activating a push plate, such as on "knowing act" doors. The SuperScan will remain in the activation circuit until the door fully closes following the automatic operation of the door. A door position switch must be used to indicate to the 10LE21 that the door has reached its fully closed position and to ignore the input of the SuperScan until the push plate activates the door again. If the door is opened manually, the 10LE21 will prohibit the input from the SuperScan from reaching the door control. The 10LE21 provides the hold open time delay; therefore the door control's time delay should be set to minimum.
Product Highlights:
- Item Number: 10LE21
- Low energy, micro-processed lockout relay module
- Desgined to inhibit the approach SuperScan on an automatic door with the door is used manually
- When the SuperScan is installed on a low energy operator that is to be used manually or automatically, the 10LE21 will allow the SuperScan to be active only when the door is triggered by activating a push plate, such as on "knowing act" doors
- SuperScan will remain in the activation circuit until the door fully closes following the automatic operation of the door
- A door position switch must be used to indicate to the 10LE21 that the door has reached its fully closed position and to ignore the input of the SuperScan until the push plate activates the door again
- If the door is opened manually, the 10LE21 will prohibit the input from the SuperScan from reaching the door control
- The 10LE21 provides the hold open time delay; therefore the door control's time delay should be set to minimum
Technical Information:
- Power Supply: 12-24 Volts AC / 15-24 Volts DC
- Operating Frequency: 4 MHz (Microprocessor)
- Power Consumption: 10 mA at rest, 50 mA Max.
- Output: 2 x SPST Relays
- Max. Voltage - Relay Contact: 60V DC, 120V AC
- Max. Current - Relay Contacts (both): 2A DC, 0.5A AC
- LENGTH: 3-1/4 Inches
- WIDTH: 2 Inches
- DEPTH: 15/16 Inch
- WIRE LENGTH: 1 Foot