• Usually Ships Following Business Day
BEA

Infrared Presence Detection Sensor IXIO-ST by BEA 10IXIOST

SKU:
10IXIOST
  • Usually Ships Following Business Day
availability:
available
MSRP: $263.27
$239.34
(You save $23.93 )
Adding to cart… The item has been added
  • Shipping Cost? For the cost of shipping your item please add the item into the shopping cart. Once the part is in the cart fill out address information in the cart under the Shipping area in the Summary section. Our system will then calculate the shipping fee based on your location and the weight of the product. This is all done before you are asked to provide payment information.

North Shore Commercial Door now carries the IXIO-ST Presence Sensor for Automatic Sliding Doors by BEA. The IXIO-ST is an effective, versatile and easy-to-use safety sensor for automatic sliding doors. It can be used for both clear door openings and side-lite protection. Visible alignment beams and infrared curtains make the IXIO-ST easy to set up and adjust. On-board LCD screen streamlines the installation and setup processes. The IXIO-ST can be adjusted into an ANSI compliant solution and has earned a comprehensive list of credentials and certifications, including UL, FCC and IP54. 

The IXIO-ST provides side-lite protection to reduce liability. Precise protection is achieved with two 24-spot, high-density, infrared safety curtains. IR curtain adjustments are easy with four visible red alignment spots projected on the ground. Programming and troubleshooting with an intelligent, menu-driven LCD screen. System integration, sensor performance monitoring and data analysis optimization performed by an on-board microprocessor. Fully monitored internally, capable of external monitoring.

Product Highlights:

  • Item Number: 10IXIOST
  • Presence sensor for automatic sliding doors
  • Can be used for both clear door openings and side-lite protection to reduce liability
  • Easy to set up and adjust with visible alignment beams and infrared curtains
  • On-board LCD screen streamlines the installation and setup processes
  • Programming and troubleshooting with an intelligent, menu-driven LCD screen 
  • Can be adjusted into an ANSI compliant solution
  • Comprehensive list of credentials and certifications including UL, FCC and IP54
  • Precise protection achieved with two 24-spot, high-density, infrared safety curtains
  • IR curtain adjustments are easy with four visible red alignment spots projected on the ground
  • System integration, sensor performance monitoring and data analysis optimization performed by an on-board microprocessor
  • Fully monitored internally, capable of external monitoring

Technical Information:

  • Technology: Active Infrared
  • Detection Mode: Presence
  • Spot Size: 2 in x 2 in
  • Max. Number of Spots: 24 per curtain
  • Max. Number of Curtains: 2
  • Output Relays:
    • Electro-Mechanical-Relay (Potential and Polarity Free)
      • Maximum Contact Current: 1 A
      • Maximum Contact Voltage: 30 VDC
      • Hold Time: 0.5 to 9 s
    • Solid-State-Relay (Potential and Polarity Free)
      • Maximum Contact Current: 400 mA
      • Maximum Contact Voltage: 42 VDC
  • Hold Time: 0.3 to 1 s
  • Test Input:
    • Electro-Mechanical-Relay (Potential and Polarity Free)
      • N/A
    • Solid-State-Relay (Potential and Polarity Free)
      • Sensitivity: Low:<1 V; High:>10 V (max. 30V)
      • Response Time on Test Request: typical:<5ms
  • Supply Voltage: 12 - 24 VAC ± 10%; 12 - 30 VDC ± 10% (to be operated from SELV compatible power supplies only)
  • Power Consumption: < 2.5 W
  • Mounting Height: 78 in - 138 in (6.5 ft - 11.5 ft)
  • Temperature Range:
    • -13˚F to +131˚F
    • 0 - 95% relative humidity, non-condensing
  • Degree of Protection: IP54
  • Applicable Directives:
    • R&TTE 19999/5/EC
    • EMC 2004/108/EC
    • MD 2006/42/EC
    • RoHS 2002/95/EC
  • Dimensions (D x W x H): 2.25 in x 10.6 in x 2.27 in
  • Cable Length: 120 in (10 ft)
  • Norm Conformance: 
    • EN 12978, EN ISO 13849-1:2008 PL <<c>> CAT.2 (under the condition that the door control system monitors the sensor at least once per door cycle)
    • IEC 61496-1:2012 ESPE Type 2
    • EN 16005: 2012 Chapter 4.6.8;
    • DIN 18650-1:2010 Chapter 5.7.4
    • BS 7036-1:1996 Chapter 8.1

ixiost-cut.pdf

ixiost-ug.pdf