• Usually Ships 4 to 7 Business Days
EMX

EMX LRS-LC Logic Controller (A-B Directionality or Increased Zone)

SKU:
LRS-LC
  • Usually Ships 4 to 7 Business Days
availability:
available
MSRP: $135.16
$122.87
(You save $12.29 )
Adding to cart… The item has been added
  • Shipping Cost? For the cost of shipping your item please add the item into the shopping cart. Once the part is in the cart fill out address information in the cart under the Shipping area in the Summary section. Our system will then calculate the shipping fee based on your location and the weight of the product. This is all done before you are asked to provide payment information.

Take the EMX Loop Replacement System (LRS-C1) Magnetoresistive Vehicle Detector Control Unit to the Next Level with the LRS-LC Logic Interface with 6 selectable functions, including A/B directional logic from North Shore Commercial Door. Now it's easy to connect two stand-alone sensors to expand the detection area. LRS-LC is designed specifically for use with EMX Loop Replacement System Vehicle Detector Control Unit LRS-C1

The LRS Logic Interface or LRS-LC works with LRS-DB Direct Burial (LRS-DB-50 or LRS-DB-100) or CS303-FP (LRS-FP-50 or LRS-FP-100) Flat Pack magnetoresistive sensors. The Logic Interface expands the functionality of the sensors by providing additional features and application-specific logic operations to meet the needs of more demanding installations. The Logic Interface allows one or two sensors to be connected and provides 6 logic functions and 2 separate relay outputs.

Once the sensor(s) has been programmed using the LRS-C1 Control Unit, the Sensor(s) store the settings and operate independently of the Control Unit and can be connected to the Logic Interface. The LRS sensor provides up to a 5ft sensing range in all directions. The LRS-LC Logic Interface allows two (2) sensors to be connected with one output to extend the detection area to 5 x 10ft. Also, A/B directional logic can be selected with an output for each direction of travel as a vehicle passes over two sensors. The status LEDs and durable housing with a standard 11-pin plug-in socket make installation quick and easy. includes black 11-pin socket base DIN rail mount

The LRS-LC Logic Interface was previously known as the CarSense CS303-L Logic Interface and is compatible with other CarSense vehicle detection products by EMX.

Product Highlights:

  • Item Number: LRS-LC
  • Loop Replacement System Logic Interface by EMX
  • For use with the Loop Replacement System (LRS-C1) Magnetoresistive Vehicle Detector Control Unit
  • Connects two stand-alone sensors to expand the detection area
  • Expands the functionality of the sensors
  • Provides additional features and application-specific logic operations to meet the needs of more demanding installations
  • Logic Interface allows one (1) or two (2) sensors to be connected to one (1) output
  • Provides six (6) selectable logic functions and two (2) separate relay outputs
  • Once the sensor(s) has been programmed using the CS303-C-1 Control Unit, the sensor(s) store the settings and operate independent of the Control Unit and can be connected to the Logic Interface
  • The LRS sensor provides up to a 5ft sensing range in all directions but the LRS-LC extends the detection area to 5 x 10ft
  • A/B directional logic can be selected with an output for each direction of travel as a vehicle passes over two sensors
  • Status LEDs and durable housing with a standard 11-pin plug-in socket make installation quick and easy
  • Includes black 11-pin socket base DIN rail mount
LRS-LC is designed specifically for use with EMX Loop Replacement System Vehicle Detector Control Unit LRS-C1

Logic Functions:

  • Two relay operation
  • A/B directional logic
  • Pulse on entry
  • Pulse on exit
  • Double relay
  • Relay 1 only

Technical Information:

  • Power Indicator: Green LED
  • Detect Indicator: 2x Red LEDs
  • Configuration Selector: 10 Position Rotary Switch
  • Outputs:
    • Relay 1: SPDT (Form C)
    • Relay 2: SPST (Form A)
  • Output Ratings: 1A @ 24 VDC/120 VAC
  • Operating Environment:
    • -40° C...82° C
    • -40° F...180° F
    • 0-95% Relative Humidity
  • Housing Material: ABS
  • Enclosure: IP30
  • Power: 12-30 VDC and 24 VAC
  • Operating Current (standby/detect):
    • One Sensor Connected: 22/35mA
    • Two Sensors Connected: 33/60mA
  • Supply Protection Circuitry: Reverse Polarity and Fuse Protected
  • Dimensions: 2.9" (73mm) x 1.2" (38mm) x 3.1" (78mm)
  • Weight: 0.25 lbs. (113 g)
  • Connector: 11 Pin Male Connector (JEDEC B11-88)
Loopless Magnetoresistive Vehicle Detector
Model Operating Range Output Power Channel Housing Rating Connection Detect-on-Stop ULTRAMETER Sensitivity Display Installation Detection Material Mounting Detection Mode Features
Control Unit (required to program sensors)
LRS-C1 EMX CS303-C-1 Relay and discrete 12-30 VDC
24 VAC
Single ABS IP30 11 position screw terminal Yes Yes In operator Above ground Presence and motion Pulse on entry/exit
Sensor Options
LRS-FP EMX CS303-FP 5 ft. radius (1.5m)
10 ft. dia. (3m)
Discrete 12-30 VDC Single Polyamide IP69K 5 wire Yes Single saw cut Ferrous metal Below ground Presence and motion Retains programmed settings
LRS-DB EMX CS303-DB 5 ft. radius (1.5m)
10 ft. dia. (3m)
Discrete 12-30 VDC Single PVC IP69K 5 wire Yes Core drill, Clamp Ferrous metal Above or Below ground Presence and motion Retains programmed settings
Accessory Unit
LRS-LC EMX CS303-L 20 ft. (6m) or more with use of multiple FP or DB Dual relay 12-30 VDC
24 VAC
Dual ABS IP30 11-pin Yes In operator Above ground Presence and motion Provides extended detection, A/B logic and more