- Usually Ships 4 to 7 Business Days
EMX
EMX LRS-LC Logic Controller (A-B Directionality or Increased Zone)
- Usually Ships 4 to 7 Business Days
- availability:
- available
Take the EMX Loop Replacement System (LRS-C1) Magnetoresistive Vehicle Detector Control Unit to the Next Level with the LRS-LC Logic Interface with 6 selectable functions, including A/B directional logic from North Shore Commercial Door. Now it's easy to connect two stand-alone sensors to expand the detection area. LRS-LC is designed specifically for use with EMX Loop Replacement System Vehicle Detector Control Unit LRS-C1
The LRS Logic Interface or LRS-LC works with LRS-DB Direct Burial (LRS-DB-50 or LRS-DB-100) or CS303-FP (LRS-FP-50 or LRS-FP-100) Flat Pack magnetoresistive sensors. The Logic Interface expands the functionality of the sensors by providing additional features and application-specific logic operations to meet the needs of more demanding installations. The Logic Interface allows one or two sensors to be connected and provides 6 logic functions and 2 separate relay outputs.
Once the sensor(s) has been programmed using the LRS-C1 Control Unit, the Sensor(s) store the settings and operate independently of the Control Unit and can be connected to the Logic Interface. The LRS sensor provides up to a 5ft sensing range in all directions. The LRS-LC Logic Interface allows two (2) sensors to be connected with one output to extend the detection area to 5 x 10ft. Also, A/B directional logic can be selected with an output for each direction of travel as a vehicle passes over two sensors. The status LEDs and durable housing with a standard 11-pin plug-in socket make installation quick and easy. includes black 11-pin socket base DIN rail mount
The LRS-LC Logic Interface was previously known as the CarSense CS303-L Logic Interface and is compatible with other CarSense vehicle detection products by EMX.
Product Highlights:
- Item Number: LRS-LC
- Loop Replacement System Logic Interface by EMX
- For use with the Loop Replacement System (LRS-C1) Magnetoresistive Vehicle Detector Control Unit
- Connects two stand-alone sensors to expand the detection area
- Works with LRS-DB (LRS-DB-50 or LRS-DB-100) Direct Burial or LRS-FP Flat Pack (LRS-FP-50 or LRS-FP-100) Magnetoresistive Sensors by EMX
- Expands the functionality of the sensors
- Provides additional features and application-specific logic operations to meet the needs of more demanding installations
- Logic Interface allows one (1) or two (2) sensors to be connected to one (1) output
- Provides six (6) selectable logic functions and two (2) separate relay outputs
- Once the sensor(s) has been programmed using the CS303-C-1 Control Unit, the sensor(s) store the settings and operate independent of the Control Unit and can be connected to the Logic Interface
- The LRS sensor provides up to a 5ft sensing range in all directions but the LRS-LC extends the detection area to 5 x 10ft
- A/B directional logic can be selected with an output for each direction of travel as a vehicle passes over two sensors
- Status LEDs and durable housing with a standard 11-pin plug-in socket make installation quick and easy
- Includes black 11-pin socket base DIN rail mount
Logic Functions:
- Two relay operation
- A/B directional logic
- Pulse on entry
- Pulse on exit
- Double relay
- Relay 1 only
Technical Information:
- Power Indicator: Green LED
- Detect Indicator: 2x Red LEDs
- Configuration Selector: 10 Position Rotary Switch
- Outputs:
- Relay 1: SPDT (Form C)
- Relay 2: SPST (Form A)
- Output Ratings: 1A @ 24 VDC/120 VAC
- Operating Environment:
- -40° C...82° C
- -40° F...180° F
- 0-95% Relative Humidity
- Housing Material: ABS
- Enclosure: IP30
- Power: 12-30 VDC and 24 VAC
- Operating Current (standby/detect):
- One Sensor Connected: 22/35mA
- Two Sensors Connected: 33/60mA
- Supply Protection Circuitry: Reverse Polarity and Fuse Protected
- Dimensions: 2.9" (73mm) x 1.2" (38mm) x 3.1" (78mm)
- Weight: 0.25 lbs. (113 g)
- Connector: 11 Pin Male Connector (JEDEC B11-88)
Model | Operating Range | Output | Power | Channel | Housing | Rating | Connection | Detect-on-Stop™ | ULTRAMETER™ Sensitivity Display | Installation | Detection Material | Mounting | Detection Mode | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Control Unit (required to program sensors) | ||||||||||||||
LRS-C1 | — | Relay and discrete | 12-30 VDC 24 VAC |
Single | ABS | IP30 | 11 position screw terminal | Yes | Yes | In operator | — | Above ground | Presence and motion | Pulse on entry/exit |
Sensor Options | ||||||||||||||
LRS-FP | 5 ft. radius (1.5m) 10 ft. dia. (3m) |
Discrete | 12-30 VDC | Single | Polyamide | IP69K | 5 wire | Yes | — | Single saw cut | Ferrous metal | Below ground | Presence and motion | Retains programmed settings |
LRS-DB | 5 ft. radius (1.5m) 10 ft. dia. (3m) |
Discrete | 12-30 VDC | Single | PVC | IP69K | 5 wire | Yes | — | Core drill, Clamp | Ferrous metal | Above or Below ground | Presence and motion | Retains programmed settings |
Accessory Unit | ||||||||||||||
LRS-LC | 20 ft. (6m) or more with use of multiple FP or DB | Dual relay | 12-30 VDC 24 VAC |
Dual | ABS | IP30 | 11-pin | Yes | — | In operator | — | Above ground | Presence and motion | Provides extended detection, A/B logic and more |