The Loop Replacement System (LRS) features advanced 3-axis, magnetoresistive sensing technology.
The sensor measures Earth’s magnetic field and responds to disturbances caused
by ferrous objects. The LRS-C1 combines this exciting new technology with a field proven hardware platform to produce a high-sensitivity, compact, and cost-effective solution for reliable vehicle detection. Three sensing elements provide magnetic field
measurement in the X, Y and Z axes, improving detection sensitivity.
In contrast to the multiple cuts and corner reliefs required for the installation of inductive loops, the small size of the detector allows for easy installation in pavement (below grade) with a single straight saw cut resulting in cost savings on labor and materials. The rugged sensor is also suitable for above grade installations, making it ideal for use in confined areas or hidden in non-ferrous architectural components for security purposes.
The EMX LRS-C1 was previously known as the CS303-C-1 CarSense 303 Control Unit and is compatible with other CarSense products by EMX.
Features:
- Three-dimensional presence detection of vehicles
- Select X, Y and/or Z axis independently
- Stand-alone sensor in either Direct Burial Probe or Flat Pack model
- Sensor stores ambient background and settings in non-volatile memory
- Remote control module for programming and additional relay contact output
- Fast response for high-speed detection
- Easy, low-cost installation
- DETECT-ON-STOP™ or (DOS®) feature will allow detection only when a vehicle has come to a complete stop on the sensor. This is a worldwide unique feature to EMX detectors. It is a major advantage if you want to ignore cross traffic in tight spaces.
- LRS-C1 Control Unit Included
- EMX LRS-DB-50 Direct Burial Sensor --Direct burial probe, 50’ – Not included
- EMX LRS-DB-100 Direct Burial Sensor--Direct burial, probe, 100’ – Not included
- EMX LRS-FP-50 Direct Burial Sensor FLAT PACK 50’ Lead Wire--Direct burial, flat pack, 50’ – Not included
- EMX Direct Burial Sensor LRS-DB-100--Direct burial, flat pack, 100’ – Not included
- EMX LRS Logic Interface by LRS-LC-- Not included
Model | Operating Range | Output | Power | Channel | Housing | Rating | Connection | Detect-on-Stop™ | ULTRAMETER™ Sensitivity Display | Installation | Detection Material | Mounting | Detection Mode | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Control Unit (required to program sensors) | ||||||||||||||
LRS-C1 | — | Relay and discrete | 12-30 VDC 24 VAC |
Single | ABS | IP30 | 11 position screw terminal | Yes | Yes | In operator | — | Above ground | Presence and motion | Pulse on entry/exit |
Sensor Options | ||||||||||||||
LRS-FP | 5 ft. radius (1.5m) 10 ft. dia. (3m) |
Discrete | 12-30 VDC | Single | Polyamide | IP69K | 5 wire | Yes | — | Single saw cut | Ferrous metal | Below ground | Presence and motion | Retains programmed settings |
LRS-DB | 5 ft. radius (1.5m) 10 ft. dia. (3m) |
Discrete | 12-30 VDC | Single | PVC | IP69K | 5 wire | Yes | — | Core drill, Clamp | Ferrous metal | Above or Below ground | Presence and motion | Retains programmed settings |
Accessory Unit | ||||||||||||||
LRS-LC | 20 ft. (6m) or more with use of multiple FP or DB | Dual relay | 12-30 VDC 24 VAC |
Dual | ABS | IP30 | 11-pin | Yes | — | In operator | — | Above ground | Presence and motion | Provides extended detection, A/B logic and more |